The category is 'Modular Cables'

  • All Manufacturers
  • Factory Pack QuantityFactory Pack Quantity
  • Jacket Material
  • RoHS
  • IP Rating
  • Unit Weight
  • Length
  • Cable Length
  • Connector End A
  • Jacket Color
  • Part # Aliases
  • Connector End B
  • Series

Image

Part Number

Manufacturer

Datasheet

Availability

Pricing(USD)

Quantity

RoHS

Mount

Conductor material

Conductor Material

Approvals

AWG max.

Bend radius (no. of ODs for fixed installation)

Bend radius (no. of ODs for flexible installation)

Cable features

Cable Types

Certification marks

Colour outer sheath

Conductor category

Conductor surface

Connections

Content

Core identification

Core layout

Cross section

Cross section (each core)

Factory colour

Flame retardant

Halogen free according to IEC 60754-2

Halogen-free

Ihs Manufacturer

Insulation Materials

Insulator Material

Jacket Material

Low smoke (according to EN 61034-2)

Low smoke according to IEC 61034-2

Manufacturer

Manufacturer part #

Manufacturer Part Number

Material (details)

Material core insulation

Material outer sheath

Max. frequency

Max. length sold by the metre

Max. temperature range (fixed installation)

Max. temperature range (flexible installation)

Min. permitted bending radius, stationary application/permanent installation

Min. temperature range (fixed installation)

Min. temperature range (flexible installation)

No. of leads

Nominal cross section conductor

Nominal voltage

Nominal voltage (details)

Nominal voltage U

Nominal voltage U0

Number-coded

Operating Temperature-Max

Operating Temperature-Min

Outer diameter approx.

Outside Ø

Package

Part Life Cycle Code

Peak operating voltage

Permitted cable outer temperature after assembling without vibration

Permitted cable outer temperature during assembling/handling

Protective conductor

Risk Rank

RoHS

Rohs Code

RoHS-compliant

Screen over stranding

Screen over stranding element

Sold per metre

Specification

Spiral lenght (max.)

Spiral length (extended)

Spiral length (min.)

Spiral length (retracted)

Stranding element

Suited for cable carriers

Twisted pair cabling (part 1)

Wire ID code

ECCN Code

Type

Min Operating Temperature

Color

Applications

Shielding

Construction

Reach Compliance Code

Number of Conductors

Connector Support Type

Halogen Free

Shielded

Temperature range

Frequency range

Outside Diameter

Standards

Rated Voltage

Number of cores

Bend radius

Test voltage

Cross Section Area

Diameter

Length

0034625-1

Mfr Part No

0034625-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

6

15

Shielded,Flame-retardant

LiYCY

According to VDE 0812

Sold per metre

Braid, fine 0.34 mm² 7-strand

25 x 0.5mm²

0.50mm²

Grey

No

PVC

0034625-1

100m

+80°C

+70°C

-40°C

-5°C

25x

250 V (not for heavy current applications)

13.70mm

No

Yes

Yes

DIN 47100

UNiTRONiC® LiYCY

Yes

When laid fixed : -30 - +80°C

For flexible use: 15 x external dia. when laid fixed: 6 x external dia.

28605-1

Mfr Part No

28605-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

10

Flame-retardant

LiYY

According to VDE 0812

Sold per metre

Braid, fine 0.34 mm² 7-strand

5 x 0.75 mmmm²

0.75mm²

Pebble grey (RAL 7032)

No

PVC

28605-1

500m

+80°C

+70°C

-40°C

-5°C

5x

250 V (not for heavy current applications)

6.90mm

No

Yes

Yes

DIN 47100

UNiTRONIC® LiYY 5X0.75

No

When laid fixed: -30 - +80°C

For flexible use: 15 x external dia.

0066205

Mfr Part No

0066205

Lapp Datasheet

-

-

Min: 1

Mult: 1

Copper

26

6

15

Shielded,Flame-retardant

LiYCY (TP) UL/CSA DIN

In accordance with VDE 0812.

Grey

Class 5 = flexible

Tinned

Sold per metre

Colour

Braid, fine strands

5 x 2 x 14mm²

0.14mm²

Dark grey

According to IEC/EN 60332-1-2

No

No

PVC

No

No

0066205

Polyvinyl chloride (PVC)

Polyvinyl chloride (PVC)

305m

+80°C

+70°C

39.6

-40°C

-5°C

10x

2

6.6

7.80mm

No

(not for heavy current applications) 250V

-40 - 80

-5 - 70

Yes

Braiding

None

Yes

Pairs

Yes (1)

DIN 47100

UNITRONIC® LiYCY (TP) UL/CSA DIN

Yes

-30 - +80 ºC°C

5

For flexible use: 15 x external Ø · When fixed: 6 x external Ø

22607-1

Mfr Part No

22607-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

22

6

15

Flame-retardant

LiYY

VDE 0815

Sold per metre

7-strand

7 x 0.34mm²

0.34mm²

Grey

No

PVC

22607-1

305m

+80°C

+70°C

-40°C

-5°C

7x

300V

6.40mm

No

250 V (not for heavy current applications)

Yes

Yes

47100

UNITRONIC® LIYY UL/CSA DIN 7xAWG22/7

No

When fixed: -30 - +80°C

For flexible use: 15 x external dia.

73220126

Mfr Part No

73220126

Lapp Datasheet

-

-

Min: 1

Mult: 1

Halogen-free,Flame-retardant,Oil-resistant,UV-resistant,PUR coating

ÖLFLEX® SPIRAL 540 P

Yellow

Class 5 = flexible

1pc(s)

Colour

Finely-stranded according to VDE 0295, Class 5

2 x 1 mm²

1mm²

Yellow

According to IEC/EN 60332-1-2

Yes

LAPP GROUP PVT LTD

Polyurethane

Lapp Group

73220126

73220126

Polyurethane

Other

Polyurethane (PUR)

+50°C

+50°C

-30°C

-30°C

2x

1

500V

500

300V

7

24mm

Active

-30 - 50

No

5.05

Yes

4500mm

5000

1500mm

1500

to VDE 0293 or VDE 0293-308

ÖLFLEX® SPIRAL 540 P

unknown

WIRE AND CABLE

No

moves: -30 - +50°C

2

1119312-1

Mfr Part No

1119312-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

15

Oil-resistant,High flexural strength

ÖLFLEX® CLASSIC 110

VDE-Reg. Nr. 7030

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class 5

12 x 1.5mm²

1.50mm²

Grey

No

1119312-1

500m

+80°C

+70°C

-40°C

-5°C

12G

500V

300/500V

300V

Yes

12mm

No

Yes

Yes

No

Black conductors with white numbering (VDE 0293)

ÖLFLEX® CLASSIC 110

-5 - +70 °C, applications with movement: · Fixed installation: -40 - +80 °C °C

15 x external dia. for wide range of applications, 4 x external dia. when permanently installed

4000V

12458-1

Mfr Part No

12458-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

10

Halogen-free,Oil-resistant,Cold-resistant,PUR coating

ÖLFLEX® 540 P

VDE REGISTRATION NUMBER 6584

Sold per metre

Finely stranded according to VDE 0293, Class 5/IEC 228 Class 55

3 x 1mm²

1mm²

Yellow

Yes

Polyurethane

12458-1

Hydrolysis resistant one PUR-MIXTURE

300m

+90°C

+90°C

-50°C

-40°C

3G

500V

300V

7.40mm

No

Yes

Yes

Wire identification colour coded according to VDE 0293 or VDE 0293-308, (7-core with printed numbering)

ÖLFLEX® 540 P 3x1.0

No

MOVED: -40 - +90 °C, FIXED: -50 - +90°C

Minimum bend radius for flexible application: 10 x external dia. · when fixed: 4 x external dia.

70002641

Mfr Part No

70002641

Lapp Datasheet

13
In Stock

  • 1: $54.690428
  • 10: $51.594743
  • 100: $48.674286
  • 500: $45.919138
  • View all price

Min: 1

Mult: 1

UV-resistant,PUR coating,Oil-resistant

ÖLFLEX® SPIRAL 400P

In accordance with: Wire according to VDE 0812/0281, sheath according to 0250/0282.

Grey

Class 5 = flexible

1pc(s)

Colour

Finely-stranded according to VDE 0295, Class 5

5 x 0.75 mmmm²

0.75mm²

Grey

No

No

Polyurethane

70002641

Polyurethane

Polyvinyl chloride (PVC)

Polyurethane (PUR)

+50°C

+50°C

-5°C

-5°C

5G

0.75

500V

300/500V

500

300V

6.9

6.70mm

-5 - 50

Yes

Yes

3000mm

3000

1000mm

1000

Black wires with white number printing (VDE 0293)

ÖLFLEX® SPIRAL 400P

No

Moved: +5 - +50°C

1119757-1

Mfr Part No

1119757-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

15

Oil-resistant,High flexural strength

CLASSIC 110

VDE-Reg. Nr. 7030

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class 5

7 x 5 mm² without gn/ge

0.50mm²

Grey

No

1119757-1

300m

+80°C

+70°C

-40°C

-5°C

7x

500V

300/500V

300V

Yes

6.70mm

No

Yes

Yes

No

Black conductors with white numbering (VDE 0293)

ÖLFLEX® CLASSIC 110

-5 - +70 °C, applications with movement: · Fixed installation: -40 - +80 °C °C

15 x external dia. for wide range of applications, 4 x external dia. when permanently installed

4000V

1119418-1

Mfr Part No

1119418-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

15

Oil-resistant,High flexural strength

CLASSIC 110

VDE-Reg. Nr. 7030

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class 5

18 x 2.5mm²

2.50mm²

Grey

No

1119418-1

100m

+80°C

+70°C

-40°C

-5°C

18G

500V

300/500V

300V

Yes

17.80mm

No

Yes

Yes

No

Black conductors with white numbering (VDE 0293)

ÖLFLEX® CLASSIC 110

-5 - +70 °C, applications with movement: · Fixed installation: -40 - +80 °C °C

15 x external dia. for wide range of applications, 4 x external dia. when permanently installed

4000V

70002705

Mfr Part No

70002705

Lapp Datasheet

-

-

Min: 1

Mult: 1

BARE COPPER

CE

UV-resistant,PUR coating,Oil-resistant

412P

In accordance with: Wire according to VDE 0812/0281, sheath according to 0250/0282.

Grey

Class 5 = flexible

1pc(s)

Numbers

Finely-stranded according to VDE 0295, Class 5

7 x 1.5mm²

1.50mm²

Grey

No

No

LAPP GROUP PVT LTD

Polyurethane

POLYVINYL CHLORIDE

POLYURETHANE

Lapp Group

70002705

70002705

Polyurethane

Polyvinyl chloride (PVC)

Polyurethane (PUR)

+50°C

+50°C

-5°C

-5°C

7G

1.5

500V

300/500V

500

300V

50 °C

5 °C

9.1

8.90mm

Active

-5 - 50

Yes

5.23

Yes

Yes

1500mm

1250

500mm

500

Black wires with white number printing (VDE 0293)

EAR99

ÖLFLEX® SPIRAL 400P

MECHANICAL ENGINEERING, APPARATUS CONSTRUCTION

NO

STRANDED

compliant

7

WIRE AND CABLE

No

Moved: +5 - +50°C

300 V

1.5 mm2

8.9 mm

22718-1

Mfr Part No

22718-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

6

20

UV-resistant,Halogen-free,Shielded

ÖLFLEX® ROBUST 215 C

In accordance with VDE: Wires: VDE 0245/0250/0281, sheath according to VDE 0250/0281.

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class5

3 x 0.75mm²

0.75mm²

Black

Yes

22718-1

100m

+80°C

+80°C

-50°C

-40°C

3G

500V

300/500V

300V

Yes

6.60mm

No

Yes

No

Black wires with white number printing (VDE 0293)

ÖLFLEX® ROBUST 215 C

Moving: -40 - +80 °C, when fixed : -50 - +80°C

For flexible use: 20 x external dia. when laid fixed: 6 x external dia.

71220118

Mfr Part No

71220118

Lapp Datasheet

-

-

Min: 1

Mult: 1

Cable

Halogen-free,Flame-retardant,Oil-resistant,UV-resistant,PUR coating

ÖLFLEX® SPIRAL 540 P

Yellow

Class 5 = flexible

1pc(s)

Colour

Finely-stranded according to VDE 0295, Class 5

4 G 0.75 mm²

0.75mm²

Yellow

According to IEC/EN 60332-1-2

Yes

Polyurethane

71220118

Polyurethane

Other

Polyurethane (PUR)

+50°C

+50°C

-30°C

-30°C

4G

0.75

500V

500

300V

7.6

29mm

-30 - 50

Yes

Compliant

Yes

4500mm

5000

1500mm

1500

to VDE 0293 or VDE 0293-308

ÖLFLEX® SPIRAL 540 P

-30 °C

Yellow

Unshielded

Halogen Free

No

moves: -30 - +50°C

29 mm

4

0034510-1

Mfr Part No

0034510-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

6

15

Shielded,Flame-retardant

LiYY

According to VDE 0812

Sold per metre

Braid, fine 0.34 mm² 7-strand

10 x 34mm²

0.34mm²

Grey

No

PVC

0034510-1

300m

+80°C

+70°C

-40°C

-5°C

10x

250 V (not for heavy current applications)

8.30mm

No

Yes

Yes

DIN 47100

UNiTRONiC® LiYY

Yes

When laid fixed : -30 - +80°C

For flexible use: 15 x external dia. when laid fixed: 6 x external dia.

1119109-1

Mfr Part No

1119109-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

15

Oil-resistant,High flexural strength

CLASSIC 110

VDE-Reg. Nr. 7030

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class 5

9 x 75mm²

0.75mm²

Grey

No

1119109-1

300m

+80°C

+70°C

-40°C

-5°C

9G

500V

300/500V

300V

Yes

9.40mm

No

Yes

Yes

No

Black conductors with white numbering (VDE 0293)

ÖLFLEX® CLASSIC 110

-5 - +70 °C, applications with movement: · Fixed installation: -40 - +80 °C °C

15 x external dia. for wide range of applications, 4 x external dia. when permanently installed

4000V

350173-1

Mfr Part No

350173-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

6

20

Shielded,Flexible

CLASSIC 100 CY

In accordance with: IEC 60227-5 HD 21.5 S3 VDE 0281 Part 5 HD 21.13 S1 VDE 0281 Part 13

Sold per metre

Finely stranded according to VDE 0295, Class 5/IEC 60228 Class 5

4 x 2.5mm²

2.50mm²

Transparent

No

350173-1

100m

+80°C

+70°C

-40°C

-5°C

4x

750V

450V

No

13.50mm

No

Yes

Yes

No

Coloured according to VDE 0293 or VDE 0293-308

ASI Bus

Moving: -5 - +70 °C, when fixed : -40 - +80°C

20 x external dia. for wide range of applications, 6 x external dia. when permanently installed

4kV

1591306-1

Mfr Part No

1591306-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

10

Shielded,Flame-retardant

J-Y(ST)Y

In Anlehnung an VDE 0815

Sold per metre

Plain copper

8 x 2 x 0.6mm

0.60mm

Grey

No

PVC

1591306-1

500m

+70°C

+50°C

-30°C

-5°C

16x

300V

300 V (not for heavy current applications)

8mm

No

Yes

Yes

Yes (1)

J-Y(ST)Y

Yes

When permanently installed: -30 - +70°C

J-Y(ST)Y

10 x external dia.

4571120

Mfr Part No

4571120

Lapp Datasheet

-

-

Min: 1

Mult: 1

M6

1pc(s)

Extra-fine stranded conductor made of plain copper wires (IEC 60228 Cl. 6)

4mm²

4mm²

No

4571120

+40°C

+40°C

-30°C

-30°C

1x

Yes

Yes

No

EB rund 4 mm²M6

-30 - +40°C

2500V

170mm

122033-1

Mfr Part No

122033-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

4

15

Oil-resistant,PUR coating

452 P

According to: VDE 0250/0281

Sold per metre

Finely-stranded according to VDE 0295, Class 5

4 x 1.5mm²

1.50mm²

Yellow

No

Polyurethane

122033-1

Polyurethane

100m

+80°C

+70°C

-40°C

-5°C

4G

500V

300/500V

300V

10.10mm

No

Yes

Yes

Coloured according to VDE 0293 or VDE 0293-308

OILFLEX® 450 P 4G1.5 NCC

No

Moving: -5 - +70 °C, when fixed : -30 - +80°C

For flexible use: 15 x external dia. · When fixed: 4 x external dia.

3000V

2170128-1

Mfr Part No

2170128-1

Lapp Datasheet

-

-

Min: 1

Mult: 1

24

Rigid,Simplex,Common shield,Twin shield

LAN (S-FTP)

Sold per metre

4 x 2 x AWG24

0.20mm²

Grey

PVC

2170128-1

PVC

100MHz

500m

8x

6.40mm

No

Yes

Yes

CAT 5e

Yes (1)

Rigid

SF/UTP

200MHz