The category is 'Multiple Conductor Cables'

  • All Manufacturers
  • Jacket Color
  • Number of Conductors
  • Cable Length
  • Factory Pack QuantityFactory Pack Quantity
  • Wire Gauge - AWG
  • Reach Compliance Code
  • Shielding
  • Ihs Manufacturer
  • Manufacturer Part Number
  • Part Life Cycle Code
  • Risk Rank
  • RoHS

Image

Part Number

Manufacturer

Datasheet

Availability

Pricing(USD)

Quantity

RoHS

Factory Lead Time

Lifecycle Status

Mount

Conductor Material

Approvals

Automotive

Cable Length (m)

Cable Types

Category

Colour outer sheath

Conductor category

Conductor surface

Core identification

ECCN (US)

EU RoHS

Flame retardant

Halogen free according to IEC 60754-2

HTS

Ihs Manufacturer

Impedance (Ohm)

Insulation DC Resistance

Insulation Diameter (mm)

Insulation Materials

Insulator Material

Jacket Material

Low smoke (according to EN 61034-2)

Low smoke according to IEC 61034-2

Manufacturer

Manufacturer Part Number

Material core insulation

Material outer sheath

Maximum Current Rating (A)

Maximum Operating Temperature

Maximum Operating Temperature (°C)

Maximum Outer Diameter (mm)

Maximum Voltage Rating

Min. permitted bending radius, stationary application/permanent installation

Minimum Operating Temperature

Minimum Operating Temperature (°C)

Nominal cross section conductor

Nominal voltage U

Operating Temperature-Max

Operating Temperature-Min

Outer diameter approx.

Part Life Cycle Code

Permitted cable outer temperature after assembling without vibration

Permitted cable outer temperature during assembling/handling

PPAP

Risk Rank

RoHS

Rohs Code

Screen over stranding

Screen over stranding element

Size (AWG)

Standards Met

Stranding element

Voltage Rating (AC)

Voltage Rating (DC)

Voltage, Rating

Packaging

Series

Part Status

ECCN Code

Type

Max Operating Temperature

Min Operating Temperature

Color

Applications

Shielding

Construction

Reach Compliance Code

Current Rating

Insulation Color

Number of Conductors

Wire Gauge

ELV

Max Voltage Rating (AC)

Connector Support Type

Wire/Cable Gauge

Jacket Color

Wire/Cable Diameter

Shield Type

Outside Diameter

Wire/Cable Color

Rated Voltage

Number of Cores

Wire and Cable Name

Number of Strands

Conductor Diameter

Strand Size

Outer Diameter

Cross Section Area

Diameter

Length

REACH SVHC

Lead Free

7-219585-2

Mfr Part No

7-219585-2

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Unconfirmed

44A1141-22-0/2/4/6-9

Mfr Part No

44A1141-22-0/2/4/6-9

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

Production (Last Updated: 10 months ago)

Cable

Tinned Copper

No

EAR99

Compliant

TE CONNECTIVITY LTD

Polyalkene

TE Connectivity

44A1141-22-0/2/4/6-9

150

3.96

600VAC

-65

Active

No

5.57

Compliant

Yes

22

600 V

600 V

Obsolete

High Performance Cable

150 °C

-65 °C

White

Shielded

compliant

4

Compliant

600 V

WIRE AND CABLE

22 AWG

White

1.19 mm

3.8354 mm

Blue

19

787.4 µm

34 AWG

Not Applicable

7171653001

Mfr Part No

7171653001

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Obsolete

57538-9

Mfr Part No

57538-9

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Unconfirmed

F359313001

Mfr Part No

F359313001

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Active

9729NH.00152

Mfr Part No

9729NH.00152

Belden Datasheet

-

-

Min: 1

Mult: 1

Tinned Copper

152

EAR99

Compliant

Low Smoke Zero Halogen

1

80

7.9

300VAC

-45

24

Active

Twisted Pair Cable

4

Chrome

Tape

0011137

Mfr Part No

0011137

Lapp Datasheet

-

-

Min: 1

Mult: 1

Bare Copper

CE; CSA; EAC; HAR; UL

No

600

Grey

Class 5 = flexible

Bare

Numbers

EAR99

Compliant

According to IEC/EN 60332-1-2

No

LAPP GROUP PVT LTD

POLYVINYL CHLORIDE

Polyvinyl Chloride

No

No

Lapp Group

0011137

Polyvinyl chloride (PVC)

Polyvinyl chloride (PVC)

70

7.3

600V

28.8

-40

1.5

500

70 °C

-40 °C

7.2

Active

-40 - 70

-5 - 90

No

5.24

Yes

None

None

16

No

Active

EAR99

Multi-Conductor Cable

PLANT ENGINEERING, INDUSTRIAL MACHINERY, MACHINE TOOLS

NO

STRANDED

compliant

3

WIRE AND CABLE

Gray

600 V

CONTROL CABLE

1.5 mm2

7.3 mm

F866663001

Mfr Part No

F866663001

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Active

0066204

Mfr Part No

0066204

Lapp Datasheet

-

-

Min: 1

Mult: 1

No

Grey

Class 5 = flexible

Tinned

Colour

EAR99

Compliant

According to IEC/EN 60332-1-2

No

No

No

Polyvinyl chloride (PVC)

Polyvinyl chloride (PVC)

38.4

2

6.4

-40 - 80

-5 - 70

No

Braiding

None

Pairs

Active

7038885

Mfr Part No

7038885

Lapp Datasheet

-

-

Min: 1

Mult: 1

No

Black

Class 6 = very flexible

Colour

EAR99

Compliant

According to IEC/EN 60332-1-2

No

No

No

Polyurethane (PUR)

0.34

4.6

-40 - 80

0 - 0

No

Active

10019944

Mfr Part No

10019944

Lapp Datasheet

-

-

Min: 1

Mult: 1

Bare Copper

No

Grey

Class 5 = flexible

Bare

Numbers

EAR99

Compliant

According to IEC/EN 60332-3-24

No

Yes

Yes

Other

Other

80

7.6

30.4

-40

2.5

500

7.6

-40 - 80

-30 - 70

No

None

None

No

Active

Shielded Multi-Conductor Cable

2

Gray

0034504

Mfr Part No

0034504

Lapp Datasheet

-

-

Min: 1

Mult: 1

Bare Copper

No

1000

LiYCY

Grey

Class 2 = stranded

Bare

Colour

EAR99

Compliant

According to IEC/EN 60332-1-2

No

PVC

Polyvinyl Chloride

No

No

Polyvinyl chloride (PVC)

Polyvinyl chloride (PVC)

+80°C

80

5.7

350V

34.2

-40°C

-40

0.34

5.7

-40 - 70

-5 - 70

No

Non-Compliant

Braiding

None

22

No

250 V

350V

UNITRONIC LiYCY

Active

Multi-Conductor Cable

Grey

4

22AWG

Pebble Gray

Braid

4

5.7mm

100m

No SVHC

3644B/20SF

Mfr Part No

3644B/20SF

3M Datasheet

-

-

Min: 1

Mult: 1

5 Weeks

No

EAR99

Compliant

8544.49.30.80

3M ELECTRONIC PRODUCTS DIVISION

3M Interconnect

3644B/20SF

Active

No

5.55

Compliant

Yes

Active

unknown

WIRE AND CABLE

30.48 m

0032434

Mfr Part No

0032434

Lapp Datasheet

-

-

Min: 1

Mult: 1

No

Black

Class 2 = stranded

Bare

Colour

EAR99

Compliant

According to IEC/EN 60332-1-2

No

No

No

Polyvinyl chloride (PVC)

2

19.3

-40 - 80

-5 - 50

No

Foil

None

Pairs

Coil|Drum

Active

3644B/24SF

Mfr Part No

3644B/24SF

3M Datasheet

-

-

Min: 1

Mult: 1

No

EAR99

Compliant

No

Compliant

30.48 m

2170267

Mfr Part No

2170267

Lapp Datasheet

-

-

Min: 1

Mult: 1

No

Other

Purple

Class 2 = stranded

Colour

EAR99

Compliant

According to IEC/EN 60332-1-2

No

No

No

Polyvinyl chloride (PVC)

76.8

2

9.6

-30 - 80

0 - 0

No

Braiding

None

Pairs

Active

3600B/24100&s;SF

Mfr Part No

3600B/24100&s;SF

3M Datasheet

-

-

Min: 1

Mult: 1

Tinned Copper

30.48

EAR99

Compliant

91

10000MOhm/10ft

0.66

Polyvinyl Chloride

80

6.42

150V

28

Roll

Active

Shielded Twisted Pair Cable

Multi Color

24

Beige

Foil/Braid

M27500-22SD3T23

Mfr Part No

M27500-22SD3T23

TE Connectivity Datasheet

-

-

Min: 1

Mult: 1

Tin Coated Copper

No

EAR99

Compliant

8544.49.30.80

Cross Linked Modified Ethylene Tetrafluoroethylene

150

3.96

600V

-65

No

22

Active

Multi-Conductor Cable

White/Blue/Orange

3

Braid

3750/50 100SF

Mfr Part No

3750/50 100SF

3M Datasheet

-

-

Min: 1

Mult: 1

Cable

Tinned Copper

EAR99

Compliant

100

PVC

Polyvinyl Chloride

75

12.4

300V

Compliant

26

50 V

50V

Roll

Shielded Twisted Pair Cable

Grey

Multi Color

50

26AWG

26 AWG

Gray

Foil Film/Braid

12.4 mm

No SVHC

1600003

Mfr Part No

1600003

Lapp Datasheet

-

-

Min: 1

Mult: 1

Copper

CE; EAC; VDE

No

EAR99

Compliant

LAPP GROUP PVT LTD

PVC

POLYVINYL CHLORIDE

POLYVINYL CHLORIDE

Lapp Group

1600003

+70°C

-40°C

70 °C

-40 °C

Active

No

5.51

Yes

Euroclass Eca

500 V

Coil|Drum

NYM-J

Active

IN DRY, DAMP OR WET INTERIORS

NO

STRANDED

compliant

19 A

7

WIRE AND CABLE

300 V

7

FLEXIBLE CORD AND FIXTURE WIRE

11.6mm

1.5 mm2

11.6 mm

50m