The category is 'Circuit Breakers'
Circuit Breakers (17)
- All Manufacturers
- Connector Type
- Fastening Type
- Features
- Ingress Protection
- Insert Material
- Material Flammability Rating
- Mounting Feature
- Mounting Type
- Number of Positions
- Operating Temperature
- Orientation
- Series
- Series:
Military, MIL-DTL-5015
Image | Part Number | Manufacturer | Datasheet | Availability | Pricing(USD) | Quantity | RoHS | Mounting Type | Mounting Feature | Contact Shape | Shell Material | Insert Material | Backshell Material, Plating | Adjustment range undelayed short-circuit release | Base Product Number | Brand | Built-in depth | Connectable conductor cross section multi-wired | Connectable conductor cross section solid-core | Connections | Contact Finish Mating | Contact Materials | Contact Sizes | Content | Degree of protection (IP) | Device construction | Dim | Factory Pack QuantityFactory Pack Quantity | Lead Free Status / RoHS Status | Manufacturer | Manufacturer Part Number | Max. temperature | Mfr | Min. temperature | Model | Mounting | Number of auxiliary contacts as normally closed contact | Number of auxiliary contacts as normally open contact | Overload release current setting | Overvoltage category | Package | Phase failure sensitive | Pollution degree | Primary Material | Product Status | Rated operating voltage | Rated operation power at AC-3, 230 V | Rated operation power at AC-3, 400 V | Rated permanent current Iu | Rated short-circuit breaking capacity lcu at 400 V, AC | RoHS | Switch off technique | Switch/button features | Switching current (max.) | Type of control element | Type of electrical connection of main circuit | Voltage type | Voltage, Rating | With integrated auxiliary switch | With integrated under voltage release | With thermal protection | Operating Temperature | Packaging | Series | Part Status | Moisture Sensitivity Level (MSL) | Termination | Connector Type | Type | Number of Positions | Color | Applications | Fastening Type | Subcategory | Contact Type | Current Rating (Amps) | Orientation | Shielding | Ingress Protection | Depth | Current Rating | Frequency | Shell Finish | Shell Size - Insert | Housing Color | Note | Shell Size, MIL | Cable Opening | Terminal Type | Includes | Features | Product Category | Height | Length | Width | Contact Finish Thickness - Mating | Material Flammability Rating |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr Part No M9F10210 | Schneider | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Bulkhead - Front Side Nut | Circular | Aluminum | -- | 44 | 1 - 25 | 1 - 25 | 16 | IP20 | -- | 4 | 3 | AC/DC | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 4 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 50 - 60 | Electroless Nickel | 14S-2 | Silver | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 3VA65807JT422AA0 | Siemens | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 1200 - 8000 | 16 | IP40 | Built-in device fixed built-in technique | -- | 0 | 0 | 320 - 800 | 800 | Rocker lever | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Plug Housing | For Female Sockets | 17 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | Cadmium | 20-29 | Olive Drab | Contacts Not Included | -- | -- | Coupling Nut, Self Locking | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 241135 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 70.5 | 1 - 25 | 1 - 25 | 16 | IP20 | -- | 3 | 2 | AC | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Male Pins | 2 | Threaded | Crimp | X | Unshielded | Fluid Resistant | 50 - 60 | Electroless Nickel | 12S-3 | Silver | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 278528 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 70.5 | 1 - 25 | 1 - 25 | 8 | IP20 | -- | 3 | 2 | AC | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 7 | Threaded | Crimp | W | Unshielded | Fluid Resistant | 50 - 60 | Cadmium | 24-10 | Olive Drab | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 190797 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 60 | 1 - 25 | 1 - 25 | 12 | IP20 | -- | 3 | 2 | AC | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Male Pins | 4 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 50 - 50 | Electroless Nickel | 20-4 | Silver | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 072733 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 9.8 - 9.8 | Screw terminals | 16 | 1pc(s) | IP20 | Built-in device fixed built-in technique | (L x W x H) 76 x 45 x 93 mm | -- | +55°C | -25°C | 0.4 - 0.63 | Yes | 690 - 690 | 0.09 | 0.12 | 0.63 | 150 | Thermomagnetic | + rotary switch | 0.63A | Turn button | Screw connection | No | No | No | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 4 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 76 | Cadmium | 14S-2 | Olive Drab | Contacts Not Included | -- | -- | -- | 93mm | 76mm | 45mm | -- | ||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 292194 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 8 (2), 12 (3) | -- | Other | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 5 | Threaded | Crimp | Z | Unshielded | Fluid Resistant | Electroless Nickel | 20-14 | Silver | Contacts Not Included | -- | -- | -- | -- | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 265333 | Eaton | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 6.2 - 6.2 | 4 (2), 12 (3) | IP20 | Built-in device fixed built-in technique | -- | 0.25 - 0.4 | Yes | 690 - 690 | 0.06 | 0.09 | 0.4 | 150 | Thermomagnetic | Turn button | Screw connection | No | No | No | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 5 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 76 | Cadmium | 24-12 | Olive Drab | Contacts Not Included | -- | -- | -- | 93 | 45 | -- | ||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 2CDS274337R0054 | ABB | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 69 | 0.75 - 25 | 0.75 - 35 | 16 | IP20 | -- | 3 | 3 | AC/DC | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Plug Housing | For Male Pins | 3 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 50 - 60 | Cadmium | 10SL-3 | Olive Drab | Contacts Not Included | -- | -- | Coupling Nut | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 2CDS274061R0634 | ABB | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 69 | 0.75 - 25 | 0.75 - 35 | 12 (2), 16 (14) | IP20 | -- | 3 | 3 | AC/DC | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 16 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | 50 - 60 | Cadmium | 24-7 | Olive Drab | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 2CCS893001R0251 | ABB | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 82.5 | 0 - 70 | 0 - 50 | 12 (2), 16 (5) | IP20 | -- | ABB | DIN Rail | 4 | 3 | No | AC/DC | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 7 | Threaded | Crimp | X | Unshielded | Fluid Resistant | 25 A | 50 - 60 | Cadmium | 18-9 | Olive Drab | Contacts Not Included | -- | Screw | -- | -- | -- | ||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 5SV33424KK14 | Siemens | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 70 | 0.75 - 35 | 0.75 - 35 | 8 | IP20 | -- | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Plug Housing | For Female Sockets | 3 | Threaded | Crimp | W | Unshielded | Fluid Resistant | 50 Hz | Cadmium | 20-19 | Olive Drab | Contacts Not Included | -- | -- | Coupling Nut | -- | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 3VL17061EH438TB1 | Siemens | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 600 - 600 | 8 (1), 12 (3) | IP20 | Built-in device fixed built-in technique | -- | 1 | 1 | 63 - 63 | 63 | Frame clamp | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Plug Housing | For Female Sockets | 4 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | Electroless Nickel | 18-13 | Silver | Contacts Not Included | -- | -- | Coupling Nut, Self Locking | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 3VL27061UH360AA0 | Siemens | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 79 - 693 | 4 | IP20 | Built-in device fixed built-in technique | -- | 0 | 0 | 25 - 63 | 63 | Screw connection | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 5 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | Cadmium | 32-63 | Olive Drab | Contacts Not Included | -- | -- | -- | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No 3VA53355EF410AA0 | Siemens | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Circular | Aluminum | -- | 1750 - 3500 | 4 (2), 8 (3), 12 (2), 16 (16) | IP40 | Built-in device fixed built-in technique | -- | 0 | 0 | 245 - 350 | 350 | Rocker lever | Other | -65°C ~ 175°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Receptacle Housing | For Female Sockets | 23 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | Cadmium | 32-6 | Olive Drab | Contacts Not Included | -- | -- | -- | -- | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No CLE-NL-C | Cooper Bussmann | Datasheet | - | - | Min: 1 Mult: 1 | Free Hanging (In-Line) | -- | Circular | Aluminum | -- | 12 (4), 16 (18) | -- | Bussmann | CLE-NL-C | -65°C ~ 200°C | Bulk | Military, MIL-DTL-5015 | Active | -- | Plug Housing | For Female Sockets | 22 | Threaded | Crimp | N (Normal) | Unshielded | Fluid Resistant | Electroless Nickel | 28-11 | Silver | Contacts Not Included | -- | -- | Coupling Nut | -- | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() | Mfr Part No M55629/6-323L | AIRPAX | Datasheet | - | - | Min: 1 Mult: 1 | Panel Mount | Flange | Aluminum | - | - | MS3450L18 | AIRPAX | Gold | Copper Alloy | 3 | Sensata | Amphenol Aerospace Operations | Bulk | Metal | Active | - | -55°C ~ 200°C | Military, MIL-DTL-5015 | Crimp | Receptacle, Female Sockets | 3 (Power) | Silver | Automotive, Military | Threaded | Circuit Breakers | 13A, 23A | W | Unshielded | Fluid Resistant | Electroless Nickel | 18-5 | - | - | - | Circuit Breakers | 50.0µin (1.27µm) | - |
M9F10210
Schneider
Package:Circuit Breakers
Price: please inquire
3VA65807JT422AA0
Siemens
Package:Circuit Breakers
Price: please inquire
241135
Eaton
Package:Circuit Breakers
Price: please inquire
278528
Eaton
Package:Circuit Breakers
Price: please inquire
190797
Eaton
Package:Circuit Breakers
Price: please inquire
072733
Eaton
Package:Circuit Breakers
Price: please inquire
292194
Eaton
Package:Circuit Breakers
Price: please inquire
265333
Eaton
Package:Circuit Breakers
Price: please inquire
2CDS274337R0054
ABB
Package:Circuit Breakers
Price: please inquire
2CDS274061R0634
ABB
Package:Circuit Breakers
Price: please inquire
2CCS893001R0251
ABB
Package:Circuit Breakers
Price: please inquire
5SV33424KK14
Siemens
Package:Circuit Breakers
Price: please inquire
3VL17061EH438TB1
Siemens
Package:Circuit Breakers
Price: please inquire
3VL27061UH360AA0
Siemens
Package:Circuit Breakers
Price: please inquire
3VA53355EF410AA0
Siemens
Package:Circuit Breakers
Price: please inquire
CLE-NL-C
Cooper Bussmann
Package:Circuit Breakers
Price: please inquire
M55629/6-323L
AIRPAX
Package:Circuit Breakers
Price: please inquire
