The category is 'Backplane Connectors - Housings'

  • All Manufacturers
  • Note
  • Number of Rows
  • Packaging
  • Part Status
  • Connector Type
  • RoHS Status
  • Factory Lead Time
  • Number of Positions
  • Moisture Sensitivity Level (MSL)
  • Series
  • Pitch
  • Connector Style

Image

Part Number

Manufacturer

Datasheet

Availability

Pricing(USD)

Quantity

RoHS

Factory Lead Time

Mount

Mounting Type

Package / Case

Housing Material

Contact Finish Mating

Contact Materials

Voltage Rated

Packaging

Published

Series

Part Status

Moisture Sensitivity Level (MSL)

Connector Type

Resistance

Number of Positions

Max Operating Temperature

Min Operating Temperature

Color

Number of Rows

Pitch

Insulation Resistance

Note

Connector Style

Connector Usage

Features

Radiation Hardening

RoHS Status

Flammability Rating

Lead Free

516-038-000-431

Mfr Part No

516-038-000-431

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Gray

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-038-000-441

Mfr Part No

516-038-000-441

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

NOT SPECIFIED

NOT SPECIFIED

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Gray

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-056-000-451

Mfr Part No

516-056-000-451

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Metal

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

56

Gray

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-020-000-551

Mfr Part No

516-020-000-551

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Panel

Varies by Contact

Bulk

2010

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

20

Green

4

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

516-090-000-211

Mfr Part No

516-090-000-211

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

90

Green

13

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-090-000-221

Mfr Part No

516-090-000-221

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

90

Green

13

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-038-000-141

Mfr Part No

516-038-000-141

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-056-000-241

Mfr Part No

516-056-000-241

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

56

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-038-000-355

Mfr Part No

516-038-000-355

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Panel

Varies by Contact

Bulk

2010

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew

ROHS3 Compliant

516-056-000-141

Mfr Part No

516-056-000-141

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

56

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-056-000-221

Mfr Part No

516-056-000-221

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Varies by Contact

Bulk

2005

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

56

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Receptacle

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

Lead Free

516-038-000-361

Mfr Part No

516-038-000-361

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Panel

Varies by Contact

Bulk

2010

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

516-038-000-561

Mfr Part No

516-038-000-561

EDAC Inc. Datasheet

-

-

Min: 1

Mult: 1

14 Weeks

Panel

Varies by Contact

Bulk

2010

516

Active

1 (Unlimited)

Housing for Non-Gendered Contacts

38

Green

9

0.150 3.81mm

Contacts Not Included

Rack and Panel

Plug

Backshell, Jackscrew, Guide Pin

ROHS3 Compliant

HM2H88P1LF

Mfr Part No

HM2H88P1LF

Amphenol ICC (FCI) Datasheet

77600
In Stock

Min: 1

Mult: 1

6 Weeks

Through Hole

Through Hole

Thermoplastic

Bulk

Millipacs®

Active

1 (Unlimited)

Shroud for Male Pins

200

125°C

-55°C

8 + 2

0.079 2.00mm

Contacts Not Included

Hard Metric, Type E

Header

No

RoHS Compliant

UL94 V-0

HM2H89P119LF

Mfr Part No

HM2H89P119LF

Amphenol ICC (FCI) Datasheet

155200
In Stock

Min: 1

Mult: 1

8 Weeks

Through Hole

Through Hole

Thermoplastic

Bulk

2006

Millipacs®

Active

1 (Unlimited)

Shroud for Male Pins

2Ohm

88

125°C

-55°C

8 + 2

0.079 2.00mm

Contacts Not Included

Hard Metric, Type F

Header

No

RoHS Compliant

UL94 V-0

HM2H88P117LF

Mfr Part No

HM2H88P117LF

Amphenol ICC (FCI) Datasheet

78400
In Stock

Min: 1

Mult: 1

8 Weeks

Through Hole

Through Hole

Thermoplastic

Bulk

Millipacs®

Active

1 (Unlimited)

Shroud for Male Pins

200

125°C

-55°C

8 + 2

0.079 2.00mm

Contacts Not Included

Hard Metric, Type E

Header

No

RoHS Compliant

UL94 V-0

70033-006LF

Mfr Part No

70033-006LF

Amphenol ICC (FCI) Datasheet

-

-

Min: 1

Mult: 1

10 Weeks

Through Hole

Thermoplastic

1kV

Bulk

Active

1 (Unlimited)

Shroud for Male Pins

78

125°C

-55°C

Gray

3

0.100 2.54mm

10GOhm

Contacts Not Included

Header

No

RoHS Compliant

09040323213520

Mfr Part No

09040323213520

HARTING Datasheet

-

-

Min: 1

Mult: 1

20 Weeks

Active

1 (Unlimited)

ROHS3 Compliant

09050483204520

Mfr Part No

09050483204520

HARTING Datasheet

-

-

Min: 1

Mult: 1

20 Weeks

Bulk

Active

1 (Unlimited)

Module without Contacts

48

2

0.200 5.08mm

Contacts Not Included

DIN 41612, Type E

ROHS3 Compliant

HM2H65P115LF

Mfr Part No

HM2H65P115LF

Amphenol ICC (FCI) Datasheet

-

-

Min: 1

Mult: 1

8 Weeks

Through Hole

Thermoplastic

Bulk

2009

Millipacs®

Active

1 (Unlimited)

Shroud for Male Pins

125

125°C

-55°C

5

0.079 2.00mm

Contacts Not Included

Hard Metric, Type AB25

Header

No

RoHS Compliant

UL94 V-0