The category is 'AC DC Desktop, Wall Adapters'
AC DC Desktop, Wall Adapters (6000)
- All Manufacturers
- Efficiency
- Series
- Output Power
- Height
- Number of Outputs
- RoHS
- Length
- Width
- Factory Pack QuantityFactory Pack Quantity
- Mounting Styles
- Output Voltage-Channel 1
- Input Voltage
Image | Part Number | Manufacturer | Datasheet | Availability | Pricing(USD) | Quantity | RoHS | Weight | AC Inlet Type | AC Plug included/required | Approvals | Center Pin Length | Connector A Polarity | Cooling Method | DC Output Connector | DC Output Cord Length | Factory Pack QuantityFactory Pack Quantity | Industry | Input Voltage-Max | Input Voltage-Min | Maximum Operating Temperature | Mechanical Style | Minimum Operating Temperature | Mounting Styles | Output Current-Channel 1 | Output Voltage-Channel 1 | RoHS | Unit Weight | Voltage-Output 1 | Packaging | Series | Connector Type | Number of Outputs | Efficiency | Input Type | Output Power | Current - Output 1 | Operating Temperature Range | Isolation Voltage | Load Regulation | Standard | Compliance | Input Voltage | Region | Height | Length | Width |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Mfr Part No TRH50A190-02E03-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug, Right Angle (2.5x5.5) | 1.8 m | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 20 C | Desktop | 2.65 A | 19 VDC | Details | TRH50A | Barrel Connector | 1 Output | Level VI | 50 W | - 20 C to + 70 C | 4.24 kVDC | Regulated | PSE | PSE | 90 VAC to 264 VAC | Universal | 31 mm | 120 mm | 52 mm | ||||||||
![]() | Mfr Part No TRH70A190-12E03-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug (2.5x5.5) | 1.8 m | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 20 C | Desktop | 3.7 A | 19 VDC | Details | 10.582189 oz | TRH70A | Barrel Connector | 1 Output | Level VI | 70 W | - 20 C to + 70 C | 4.24 kVDC | Regulated | PSE | 90 VAC to 264 VAC | Universal | 31 mm | 120 mm | 52 mm | |||||||||
![]() | Mfr Part No TRH150A120-1424E471-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | 4 Pin DIN Plug | 950 mm | 1 | Industrial | + 65 C | - 30 C | Desktop | 12.5 A | 12 VDC | Details | 1.653 lbs | TRH150A | DIN Connector | 1 Output | Level VI, CoC Tier 2 | 150 W | - 30 C to + 65 C | Regulated | 90 VAC to 264 VAC | Universal | 41 mm | 180 mm | 74 mm | ||||||||||||||||||
![]() | Mfr Part No TR30M120-35E03-Level-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | EN60601-1, UL60601-1 | 9.5 mm | Center Positive | Convection | 1.7 mm Barrel Plug (1.7x4) | 1.8 m | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | 0 C | Desktop | 2.5 A | 12 VDC | Details | 12 V | TR30M | Barrel Connector | 1 Output | 82 % | 30 W | 2.5 A | 0 C to + 60 C | 5.66 kVDC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 30 mm | 110 mm | 50 mm | ||||||||
![]() | Mfr Part No TRH100A120-40E12-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | CE, cUL, EN60950-1, IEC60950-1, UL60950-1 | 9.5 mm | Center Positive | Convection | 1.7 mm Barrel Plug, Right Angle (1.7x4) | 1.2 m | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 30 C | Desktop | 8.34 A | 12 VDC | Details | TRH100A | Barrel Connector | 1 Output | Level VI | 100 W | - 30 C to + 70 C | 4.24 kVDC | Regulated | PSE | PSE | 90 VAC to 264 VAC | Universal | 37 mm | 142 mm | 58 mm | ||||||||
![]() | Mfr Part No MTE200-19SX-F-W-C2 | ETA-USA | Datasheet | - | - | Min: 1 Mult: 1 | C2 | Required | 4 Pin DIN Plug | 1 m | 1 | Medical | Desktop | 10.53 A | 19 V | Details | 2.205 lbs | EN60601-1 | DIN Connector | 1 Output | Level V | 200 W | Not Regulated | 90 VAC to 264 VAC | 60 mm | 188 mm | 104.5 mm | ||||||||||||||||||||
![]() | Mfr Part No MDL60-36SX-W | ETA-USA | Datasheet | - | - | Min: 1 Mult: 1 | Required | EN60601-1 | 1 | Medical | Desktop | 1.8 A | 36 V | Details | 1 Output | Level V | 60 W | Regulated | EN60601-1 | 90 VAC to 264 VAC | Universal | 38.5 mm | 170 mm | 64 mm | |||||||||||||||||||||||
![]() | Mfr Part No TRH150A240-02E12-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | 12 mm | Center Positive | 2.5 mm Barrel Plug, Right Angle (2.5x5.5) | 1.2 m | 1 | Industrial | + 65 C | - 30 C | Desktop | 6.25 A | 24 VDC | Details | 1.653 lbs | TRH150A | Barrel Connector | 1 Output | Level VI, CoC Tier 2 | 150 W | - 30 C to + 65 C | Regulated | 90 VAC to 264 VAC | Universal | 41 mm | 180 mm | 74 mm | ||||||||||||||||
![]() | Mfr Part No TR100M180-02E13-LVL-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | EN60601-1, UL60601-1 | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug, Right Angle (2.5x5.5) | 1.8 m | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | - 20 C | Desktop | 5.56 A | 18 VDC | Details | 1.069 lbs | Bulk | TR100M | Barrel Connector | 1 Output | 88 % | 100 W | - 20 C to + 60 C | 4 kVAC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 37 mm | 142 mm | 58 mm | |||||||
![]() | Mfr Part No TRH70A120-39E01-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | 9 mm | Center Positive | Convection | 1.35 mm Barrel Plug (1.35x3.5) | 720 mm | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 20 C | Desktop | 5.8 A | 12 VDC | Details | TRH70A | Barrel Connector | 1 Output | Level VI | 70 W | - 20 C to + 70 C | 4.24 kVDC | Regulated | 90 VAC to 264 VAC | Universal | 31 mm | 120 mm | 52 mm | |||||||||||
![]() | Mfr Part No TRH70A240-35E03-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | 9.5 mm | Center Positive | Convection | 1.7 mm Barrel Plug (1.7x4) | 1.8 m | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 20 C | Desktop | 3 A | 24 VDC | Details | TRH70A | Barrel Connector | 1 Output | Level VI | 70 W | - 20 C to + 70 C | 4.24 kVDC | Regulated | 90 VAC to 264 VAC | Universal | 31 mm | 120 mm | 52 mm | |||||||||||
![]() | Mfr Part No TR60M48-12E03-Level-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | 345.000004 g | Required | EN60601-1, UL60601-1 | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug (2.5x5.5) | 1.8 m | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | 0 C | Desktop | 1.25 A | 48 VDC | Details | 12.169517 oz | TR60M | Barrel Connector | 1 Output | 87 % | 60 W | 0 C to + 60 C | 5.66 kVDC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 30.5 mm | 132 mm | 58 mm | |||||||
![]() | Mfr Part No MTE200-20SX-F-W-C2 | ETA-USA | Datasheet | - | - | Min: 1 Mult: 1 | C2 | Required | 4 Pin DIN Plug | 1 m | 1 | Medical | Desktop | 10 A | 20 V | Details | 2.205 lbs | EN60601-1 | DIN Connector | 1 Output | Level V | 200 W | Not Regulated | 90 VAC to 264 VAC | 60 mm | 188 mm | 104.5 mm | ||||||||||||||||||||
![]() | Mfr Part No TRH50A280-01E12-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Included | EN60950-1, IEC60950-1, UL60950-1 | 12 mm | Center Positive | 2.1 mm Barrel Plug, Right Angle (2.1x5.5) | 1.2 m | 1 | Industrial | + 70 C | - 20 C | Desktop | 1.8 A | 28 VDC | Details | 10.582189 oz | TRH50A | Barrel Connector | 1 Output | Level VI, CoC Tier 2 | 50 W | - 20 C to + 70 C | Regulated | EN60950-1, IEC60950-1, UL60950-1 | 90 VAC to 264 VAC | Universal | 31 mm | 120 mm | 52 mm | |||||||||||||
![]() | Mfr Part No TR30M090-12E02-Level-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | 220.000011 g | EN60601-1, UL60601-1 | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug (2.5x5.5) | 1.2 m | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | 0 C | Desktop | 3 A | 9 VDC | Details | 7.760272 oz | 9 V | TR30M | Barrel Connector | 1 Output | 82 % | 30 W | 3 A | 0 C to + 60 C | 5.66 kVDC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 30 mm | 110 mm | 50 mm | ||||||
![]() | Mfr Part No TR100M150-02E12-LVL-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | EN60601-1, UL60601-1 | 12 mm | Center Positive | Convection | 2.5 mm Barrel Plug, Right Angle (2.5x5.5) | 1.5 m | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | - 20 C | Desktop | 6.67 A | 15 VDC | Details | 1.069 lbs | TR100M | Barrel Connector | 1 Output | 88 % | 100 W | - 20 C to + 60 C | 4 kVAC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 37 mm | 142 mm | 58 mm | ||||||||
![]() | Mfr Part No 96PSA-A90W19V1-2 | Advantech | Datasheet | - | - | Min: 1 Mult: 1 | CE, CUL, IEC, UL 60950 | 11 mm | 2.5 mm Barrel Plug (2.5x5.5) | 1.5 m | 1 | Industrial | + 40 C | 0 C | Desktop | 4.7 A | 19 V | Details | Barrel Connector | 1 Output | Level VI | AC | 90 W | 0 C to + 40 C | Not Regulated | CE, CUL, IEC, UL 60950 | 100 VAC to 240 VAC | Universal | 30.9 mm | 129 mm | 51 mm | ||||||||||||||||
![]() | Mfr Part No TRH100A180-11E13-Level-VI | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | Required | 12 mm | Center Positive | Convection | 2.1 mm Barrel Plug (2.1x5.5) | 1.8 m | 1 | Industrial | 264 VAC | 90 VAC | + 70 C | External | - 30 C | Desktop | 5.56 A | 18 VDC | Details | 1.069 lbs | TRH100A | Barrel Connector | 1 Output | Level VI | 100 W | - 30 C to + 70 C | 4.24 kVDC | Regulated | PSE | 90 VAC to 264 VAC | Universal | 37 mm | 142 mm | 58 mm | |||||||||
![]() | Mfr Part No TR30M050-39E01-Level-V | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | EN60601-1, UL60601-1 | 9 mm | Center Positive | Convection | 1.35 mm Barrel Plug (1.35x3.5) | 720 mm | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | 0 C | Desktop | 4 A | 5 VDC | Details | 5 V | TR30M | Barrel Connector | 1 Output | 76 % | 30 W | 4 A | 0 C to + 60 C | 5.66 kVDC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 30 mm | 110 mm | 50 mm | ||||||||
![]() | Mfr Part No TR60M15-11E11-LVLV | Cincon | Datasheet | - | - | Min: 1 Mult: 1 | 345.000004 g | Required | EN60601-1, UL60601-1 | 12 mm | Center Positive | Convection | 2.1 mm Barrel Plug (2.1x5.5) | 1 | Medical | 264 VAC | 90 VAC | + 60 C | External | 0 C | Desktop | 4 A | 15 VDC | Details | 12.169517 oz | TR60M | Barrel Connector | 1 Output | 85 % | 60 W | 0 C to + 60 C | 5.66 kVDC | Regulated | EN60601-1, UL60601-1 | 90 VAC to 264 VAC | Universal | 30.5 mm | 132 mm | 58 mm |
TRH50A190-02E03-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH70A190-12E03-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH150A120-1424E471-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR30M120-35E03-Level-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH100A120-40E12-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
MTE200-19SX-F-W-C2
ETA-USA
Package:AC DC Desktop, Wall Adapters
Price: please inquire
MDL60-36SX-W
ETA-USA
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH150A240-02E12-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR100M180-02E13-LVL-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH70A120-39E01-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH70A240-35E03-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR60M48-12E03-Level-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
MTE200-20SX-F-W-C2
ETA-USA
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH50A280-01E12-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR30M090-12E02-Level-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR100M150-02E12-LVL-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
96PSA-A90W19V1-2
Advantech
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TRH100A180-11E13-Level-VI
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR30M050-39E01-Level-V
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
TR60M15-11E11-LVLV
Cincon
Package:AC DC Desktop, Wall Adapters
Price: please inquire
