The category is 'AC DC Desktop, Wall Adapters'

  • All Manufacturers
  • Efficiency
  • Series
  • Output Power
  • Height
  • Number of Outputs
  • RoHS
  • Length
  • Width
  • Factory Pack QuantityFactory Pack Quantity
  • Mounting Styles
  • Output Voltage-Channel 1
  • Input Voltage

Image

Part Number

Manufacturer

Datasheet

Availability

Pricing(USD)

Quantity

RoHS

Weight

AC Inlet Type

AC Plug included/required

Approvals

Center Pin Length

Connector A Polarity

Cooling Method

DC Output Connector

DC Output Cord Length

Factory Pack QuantityFactory Pack Quantity

Industry

Input Voltage-Max

Input Voltage-Min

Maximum Operating Temperature

Mechanical Style

Minimum Operating Temperature

Mounting Styles

Output Current-Channel 1

Output Voltage-Channel 1

RoHS

Unit Weight

Voltage-Output 1

Packaging

Series

Connector Type

Number of Outputs

Efficiency

Input Type

Output Power

Current - Output 1

Operating Temperature Range

Isolation Voltage

Load Regulation

Standard

Compliance

Input Voltage

Region

Height

Length

Width

TRH50A190-02E03-Level-VI

Mfr Part No

TRH50A190-02E03-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1

12 mm

Center Positive

Convection

2.5 mm Barrel Plug, Right Angle (2.5x5.5)

1.8 m

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 20 C

Desktop

2.65 A

19 VDC

Details

TRH50A

Barrel Connector

1 Output

Level VI

50 W

- 20 C to + 70 C

4.24 kVDC

Regulated

PSE

PSE

90 VAC to 264 VAC

Universal

31 mm

120 mm

52 mm

TRH70A190-12E03-Level-VI

Mfr Part No

TRH70A190-12E03-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

12 mm

Center Positive

Convection

2.5 mm Barrel Plug (2.5x5.5)

1.8 m

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 20 C

Desktop

3.7 A

19 VDC

Details

10.582189 oz

TRH70A

Barrel Connector

1 Output

Level VI

70 W

- 20 C to + 70 C

4.24 kVDC

Regulated

PSE

90 VAC to 264 VAC

Universal

31 mm

120 mm

52 mm

TRH150A120-1424E471-Level-VI

Mfr Part No

TRH150A120-1424E471-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

4 Pin DIN Plug

950 mm

1

Industrial

+ 65 C

- 30 C

Desktop

12.5 A

12 VDC

Details

1.653 lbs

TRH150A

DIN Connector

1 Output

Level VI, CoC Tier 2

150 W

- 30 C to + 65 C

Regulated

90 VAC to 264 VAC

Universal

41 mm

180 mm

74 mm

TR30M120-35E03-Level-V

Mfr Part No

TR30M120-35E03-Level-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

EN60601-1, UL60601-1

9.5 mm

Center Positive

Convection

1.7 mm Barrel Plug (1.7x4)

1.8 m

1

Medical

264 VAC

90 VAC

+ 60 C

External

0 C

Desktop

2.5 A

12 VDC

Details

12 V

TR30M

Barrel Connector

1 Output

82 %

30 W

2.5 A

0 C to + 60 C

5.66 kVDC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

30 mm

110 mm

50 mm

TRH100A120-40E12-Level-VI

Mfr Part No

TRH100A120-40E12-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

CE, cUL, EN60950-1, IEC60950-1, UL60950-1

9.5 mm

Center Positive

Convection

1.7 mm Barrel Plug, Right Angle (1.7x4)

1.2 m

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 30 C

Desktop

8.34 A

12 VDC

Details

TRH100A

Barrel Connector

1 Output

Level VI

100 W

- 30 C to + 70 C

4.24 kVDC

Regulated

PSE

PSE

90 VAC to 264 VAC

Universal

37 mm

142 mm

58 mm

MTE200-19SX-F-W-C2

Mfr Part No

MTE200-19SX-F-W-C2

ETA-USA Datasheet

-

-

Min: 1

Mult: 1

C2

Required

4 Pin DIN Plug

1 m

1

Medical

Desktop

10.53 A

19 V

Details

2.205 lbs

EN60601-1

DIN Connector

1 Output

Level V

200 W

Not Regulated

90 VAC to 264 VAC

60 mm

188 mm

104.5 mm

MDL60-36SX-W

Mfr Part No

MDL60-36SX-W

ETA-USA Datasheet

-

-

Min: 1

Mult: 1

Required

EN60601-1

1

Medical

Desktop

1.8 A

36 V

Details

1 Output

Level V

60 W

Regulated

EN60601-1

90 VAC to 264 VAC

Universal

38.5 mm

170 mm

64 mm

TRH150A240-02E12-Level-VI

Mfr Part No

TRH150A240-02E12-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

12 mm

Center Positive

2.5 mm Barrel Plug, Right Angle (2.5x5.5)

1.2 m

1

Industrial

+ 65 C

- 30 C

Desktop

6.25 A

24 VDC

Details

1.653 lbs

TRH150A

Barrel Connector

1 Output

Level VI, CoC Tier 2

150 W

- 30 C to + 65 C

Regulated

90 VAC to 264 VAC

Universal

41 mm

180 mm

74 mm

TR100M180-02E13-LVL-V

Mfr Part No

TR100M180-02E13-LVL-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

EN60601-1, UL60601-1

12 mm

Center Positive

Convection

2.5 mm Barrel Plug, Right Angle (2.5x5.5)

1.8 m

1

Medical

264 VAC

90 VAC

+ 60 C

External

- 20 C

Desktop

5.56 A

18 VDC

Details

1.069 lbs

Bulk

TR100M

Barrel Connector

1 Output

88 %

100 W

- 20 C to + 60 C

4 kVAC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

37 mm

142 mm

58 mm

TRH70A120-39E01-Level-VI

Mfr Part No

TRH70A120-39E01-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

9 mm

Center Positive

Convection

1.35 mm Barrel Plug (1.35x3.5)

720 mm

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 20 C

Desktop

5.8 A

12 VDC

Details

TRH70A

Barrel Connector

1 Output

Level VI

70 W

- 20 C to + 70 C

4.24 kVDC

Regulated

90 VAC to 264 VAC

Universal

31 mm

120 mm

52 mm

TRH70A240-35E03-Level-VI

Mfr Part No

TRH70A240-35E03-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

9.5 mm

Center Positive

Convection

1.7 mm Barrel Plug (1.7x4)

1.8 m

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 20 C

Desktop

3 A

24 VDC

Details

TRH70A

Barrel Connector

1 Output

Level VI

70 W

- 20 C to + 70 C

4.24 kVDC

Regulated

90 VAC to 264 VAC

Universal

31 mm

120 mm

52 mm

TR60M48-12E03-Level-V

Mfr Part No

TR60M48-12E03-Level-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

345.000004 g

Required

EN60601-1, UL60601-1

12 mm

Center Positive

Convection

2.5 mm Barrel Plug (2.5x5.5)

1.8 m

1

Medical

264 VAC

90 VAC

+ 60 C

External

0 C

Desktop

1.25 A

48 VDC

Details

12.169517 oz

TR60M

Barrel Connector

1 Output

87 %

60 W

0 C to + 60 C

5.66 kVDC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

30.5 mm

132 mm

58 mm

MTE200-20SX-F-W-C2

Mfr Part No

MTE200-20SX-F-W-C2

ETA-USA Datasheet

-

-

Min: 1

Mult: 1

C2

Required

4 Pin DIN Plug

1 m

1

Medical

Desktop

10 A

20 V

Details

2.205 lbs

EN60601-1

DIN Connector

1 Output

Level V

200 W

Not Regulated

90 VAC to 264 VAC

60 mm

188 mm

104.5 mm

TRH50A280-01E12-Level-VI

Mfr Part No

TRH50A280-01E12-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Included

EN60950-1, IEC60950-1, UL60950-1

12 mm

Center Positive

2.1 mm Barrel Plug, Right Angle (2.1x5.5)

1.2 m

1

Industrial

+ 70 C

- 20 C

Desktop

1.8 A

28 VDC

Details

10.582189 oz

TRH50A

Barrel Connector

1 Output

Level VI, CoC Tier 2

50 W

- 20 C to + 70 C

Regulated

EN60950-1, IEC60950-1, UL60950-1

90 VAC to 264 VAC

Universal

31 mm

120 mm

52 mm

TR30M090-12E02-Level-V

Mfr Part No

TR30M090-12E02-Level-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

220.000011 g

EN60601-1, UL60601-1

12 mm

Center Positive

Convection

2.5 mm Barrel Plug (2.5x5.5)

1.2 m

1

Medical

264 VAC

90 VAC

+ 60 C

External

0 C

Desktop

3 A

9 VDC

Details

7.760272 oz

9 V

TR30M

Barrel Connector

1 Output

82 %

30 W

3 A

0 C to + 60 C

5.66 kVDC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

30 mm

110 mm

50 mm

TR100M150-02E12-LVL-V

Mfr Part No

TR100M150-02E12-LVL-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

EN60601-1, UL60601-1

12 mm

Center Positive

Convection

2.5 mm Barrel Plug, Right Angle (2.5x5.5)

1.5 m

1

Medical

264 VAC

90 VAC

+ 60 C

External

- 20 C

Desktop

6.67 A

15 VDC

Details

1.069 lbs

TR100M

Barrel Connector

1 Output

88 %

100 W

- 20 C to + 60 C

4 kVAC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

37 mm

142 mm

58 mm

96PSA-A90W19V1-2

Mfr Part No

96PSA-A90W19V1-2

Advantech Datasheet

-

-

Min: 1

Mult: 1

CE, CUL, IEC, UL 60950

11 mm

2.5 mm Barrel Plug (2.5x5.5)

1.5 m

1

Industrial

+ 40 C

0 C

Desktop

4.7 A

19 V

Details

Barrel Connector

1 Output

Level VI

AC

90 W

0 C to + 40 C

Not Regulated

CE, CUL, IEC, UL 60950

100 VAC to 240 VAC

Universal

30.9 mm

129 mm

51 mm

TRH100A180-11E13-Level-VI

Mfr Part No

TRH100A180-11E13-Level-VI

Cincon Datasheet

-

-

Min: 1

Mult: 1

Required

12 mm

Center Positive

Convection

2.1 mm Barrel Plug (2.1x5.5)

1.8 m

1

Industrial

264 VAC

90 VAC

+ 70 C

External

- 30 C

Desktop

5.56 A

18 VDC

Details

1.069 lbs

TRH100A

Barrel Connector

1 Output

Level VI

100 W

- 30 C to + 70 C

4.24 kVDC

Regulated

PSE

90 VAC to 264 VAC

Universal

37 mm

142 mm

58 mm

TR30M050-39E01-Level-V

Mfr Part No

TR30M050-39E01-Level-V

Cincon Datasheet

-

-

Min: 1

Mult: 1

EN60601-1, UL60601-1

9 mm

Center Positive

Convection

1.35 mm Barrel Plug (1.35x3.5)

720 mm

1

Medical

264 VAC

90 VAC

+ 60 C

External

0 C

Desktop

4 A

5 VDC

Details

5 V

TR30M

Barrel Connector

1 Output

76 %

30 W

4 A

0 C to + 60 C

5.66 kVDC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

30 mm

110 mm

50 mm

TR60M15-11E11-LVLV

Mfr Part No

TR60M15-11E11-LVLV

Cincon Datasheet

-

-

Min: 1

Mult: 1

345.000004 g

Required

EN60601-1, UL60601-1

12 mm

Center Positive

Convection

2.1 mm Barrel Plug (2.1x5.5)

1

Medical

264 VAC

90 VAC

+ 60 C

External

0 C

Desktop

4 A

15 VDC

Details

12.169517 oz

TR60M

Barrel Connector

1 Output

85 %

60 W

0 C to + 60 C

5.66 kVDC

Regulated

EN60601-1, UL60601-1

90 VAC to 264 VAC

Universal

30.5 mm

132 mm

58 mm