The manufacturer is 'DEGSON'

    • Ambient temperature (operation)
    • Ambient temperature (storage/transportation)
    • Installation location
    • Packing unit
    • Products weight (without packaging)
    • length
    • width
    • Action time
    • CoilResistance
    • Contact Materials
    • Contact composition
    • Contact mechanism
    • All Manufacturers:

      DEGSON

    Image

    Part Number

    Manufacturer

    Datasheet

    Availability

    Pricing(USD)

    Quantity

    RoHS

    Action time

    Ambient temperature (operation)

    Ambient temperature (storage/transportation)

    CoilResistance

    Contact composition

    Contact Materials

    Contact mechanism

    ElectricalLife

    environment humidity

    Installation location

    Maximum allowable voltage

    Maximum contact current

    Maximum contact voltage

    Maximum switching frequency (mechanical)

    Maximum switching frequency (rated load)

    Operation mode

    Overvoltage category

    Packing unit

    Pollution level

    Power consumption under rated conditions

    Products weight (without packaging)

    Protection level

    Rated input voltage UN

    Relay socket

    Reset time

    Reset voltage

    Shock proof

    Standards/Regulations

    Test voltage PDT/PDT

    Test voltage relay coil/relay contact

    Typical input current under UN

    Vibration resistant

    Withstand voltage (between coil and contact)

    Withstand voltage (between contacts of the same pole)

    Withstand voltage (between different pole contacts)

    Contact resistance

    Insulation resistance

    Mechanical life

    insulation

    Operating voltage

    Height

    length

    width

    Single relay-DRPL-4C-L-A220-02A(H)

    Mfr Part No

    Single relay-DRPL-4C-L-A220-02A(H)

    DEGSON Datasheet

    -

    -

    Min: 1

    Mult: 1

    <20ms

    -25 °C ... 55 °C

    -25 °C ... 55 °C

    5647Ω

    4C

    Ag alloy

    single

    >1×105

    35%~85%RH

    Arbitrary

    1.1

    10A

    AC240V DC28V

    18000 times/h

    1800 times/h

    100% work factor

    20

    3

    2.5VA

    80

    IP50

    220VAC

    DPTF14A-3-02A(H)

    <20ms

    ≥30%

    10G

    IEC 61810-1 IEC 60664

    1000VAC/1min

    1500VAC/1min

    13.6mA

    10-55Hz

    1500VAC/1min

    1000VAC/1min

    1000VAC/1min

    ≤100mΩ

    ≥100MΩ

    >1×107

    Basic isolation

    ≤80%

    36mm

    41.5mm

    28mm

    Single relay-DRPL-2C-L-A220-02A(H)

    Mfr Part No

    Single relay-DRPL-2C-L-A220-02A(H)

    DEGSON Datasheet

    -

    -

    Min: 1

    Mult: 1

    <20ms

    -25 °C ... 55 °C

    -25 °C ... 55 °C

    14116Ω

    2C

    Ag alloy

    single

    >1×105

    35%~85%RH

    Arbitrary

    1.1

    10A

    AC240V DC28V

    18000 times/h

    1800 times/h

    100% work factor

    20

    3

    0.9W

    40

    IP50

    220VAC

    DPTF08A-3-02A(H)

    <20ms

    ≥10%

    10G

    IEC 61810-1 IEC 60664

    1000VAC/1min

    1500VAC/1min

    37.5mA

    10-55Hz

    1500VAC/1min

    1000VAC/1min

    1000VAC/1min

    ≤100mΩ

    ≥100MΩ

    >1×107

    Basic isolation

    ≤75%

    36mm

    21.5mm

    28mm